ULT-2000RM 3U Rackmount Backup UPS
| Model Type |
ULTIMATE LCD RM |
 |
| Model Name |
ULT-2000RM LCD |
 |
| Power Rating |
2000VA |
 |
 |
AC INPUT
|
 |
| AC Input Voltage |
100V:76V~130V
110V:80V~138V 115V:83.5V~140V 120V:87V~140V 208V:152V~260V
220V:160V~276V 230V:167V~280V 240V:174V~280V |
 |
| AC Input Frequency |
50 or 60 Hz+/-3 Hz |
 |
| AC Input Phase |
Single |
 |
| AC Input Power factor |
>= 0.98 |
 |
 |
AC OUTPUT
|
 |
| AC Output Voltage |
100V/110V/115V/120V
or 208V/220V/230V/240V |
 |
| AC Output Frequency |
50Hz/60Hz (Auto
detection) |
 |
| AC Output Frequency Stability |
(+/-0.5%) |
 |
| AC Output Voltage Regulation |
(+/-2%) |
 |
| AC Output Powerfactor |
0.7 (lagging) |
 |
| AC Output Hamonic distortion |
<3% of T.H.D. at
linear load |
 |
| AC Output Overload detection |
105% for 10 seconds
and 130% +/- 10% for 300ms |
 |
| AC Output Crest factor ratio |
( 3:1 ) |
 |
 |
 |
TRANSFER
|
 |
| Transfer Power failure Recovery |
0 ms |
 |
| Transfer Overload Disappear |
Auto transfer to UPS |
 |
| Transfer UPS to By Pass or Vice
Versa |
0 ms |
 |
 |
NOISE
|
 |
| Noise Level 1m Distance |
< 52dBA |
 |
 |
PROTECTION
|
 |
| Protection Spike |
150 Joules |
 |
 |
BATTERY
|
 |
| Battery Type |
Sealed lead acid
battery, free-maintenance |
 |
| Battery Protection |
Cut off without
draining any current when battery low |
 |
| Battery DC Voltage |
72V |
 |
 |
BACKUP TIME
|
 |
| Battery Backup Time Full Load |
9 minutes |
 |
| Battery Backup Time Half Load |
25 minutes |
 |
| Battery Recharge Time |
About 8 hours to 90%
after fully discharged |
 |
 |
PHYSICAL
|
 |
| Physical Weight lbs Tower |
N/A |
 |
| Physical Weight kgs RM |
28 |
 |
| Physical Weight lbs RM |
(61.6lb) |
 |
| Physical Dimension mm Tower |
N/A |
 |
| Physical Dimension
inch Tower |
N/A |
 |
| Physical Dimension mm RM |
19 x 15.7 x 5.1 |
 |
| Physical Dimension inch RM |
(16.9 |
 |
 |
INDICATOR
|
 |
| LCD |
LCD |
 |
| LCD Indicators Status |
Indicate line,
bypass, inv, backup, fault, bat capacity, load capacity, I/P
frequency, O/P voltage, O/P frequency, inside temperature, fault
status |
 |
 |
ALARM
|
 |
| Alarm Battery Discharge |
The first warning
will beep every 4 seconds to indicate battery in use. The second
warning will beep every 1 second to signal battery low condition |
 |
| Alarm UPS Fault |
Continuous beeping
sound |
 |
 |
INTERFACE
|
 |
| Interface Dry Contact |
Sends AC fail and
battery low signals, and receives shutdown signal from computer |
 |
| Interface RS-232 |
Detect battery low,
Schedule UPS on/off, AC input/output power status display |
 |
| Interface Option |
Novell, SNMP,
Windows NT, Window 95/98/2000/ME/XP |
 |
 |
ENVIRONMENT
|
 |
| Environment Temperature |
0 deg C ~ 40 deg C |
 |
| Environment Humidity |
0%~95% (Non
condensing) |
 |
| ShowOrder |
106 |
|